High-speed building wire insulation lines
Engineered to insulate low-voltage building wire with various thermoplastic materials including flame-retardants such as reticulated polyethylene and halogen-free compounds.
The range is completed by THHN cable manufacturing equipment where cables are jacketed with nylon.
Line types
BIA1: 1 and 2 extruders for skin/stripe process
BIA2: 2 extruders, high productivity
BI A3: 3 extruders for skin/stripe quick colour change
BI A4: THHN wire insulation and sheathing
BI A4-HS: THHN wire insulation and sheathing in line with rod break-down machine
Performance
| Conductor | Conductor section | Max. wire Ø | Insulation | Jacketing | Max. speed |
Solid (Class 1) Stranded (Class 2) Bunched (Class 5)
| 0,5 - 10,0 mm² 1,0 - 16,0 mm² 0,5 - 25,0 mm²
| 10 mm
| PVC PE XLPE XLPE Liquid Silane HFFR PP PUR TPE | PA
| 1500 m/min 2400 m/min*
|
* Tandem with rod break-down machine
Technical features
+ Quick stripe/skin colour change system
+ Minimum distance between extruder and extrusion head, thus no material stagnation and constant work pressure
+ Volumetric and gravimetric dosing stations for base material, colour and/or catalyst
+ Cooling trough equipped with thermoregulated and motorised multi-pass sections
+ High speed dual automatic take-ups AV 1000/1250 D without foundations